Home
Used NMR Equipment
       Complete Systems
       Varian Parts
       Bruker Parts
       Jeol Parts
       MRI Parts
       Magnets
Services
Experience
Useful Stuff
Environmental Impact
Contact/Impressum

Used Bruker NMR equipment currently on offer

Consoles

  • Avance3 600 MHz: 4 channel console, dual bay, gradient amplifier, diverse amplifiers available
  • Avance2+ 600 MHz: 3 channel console, single bay, gradient amplifier, diverse amplifiers available
  • Avance3 500 MHz: 3 channel console, single bay, gradient amplifier, diverse amplifiers available
  • Avance2 500 MHz: 2 channel console, single bay, gradient amplifier, diverse amplifiers available
  • Avance2 400 MHz: 2-4 channel console, dual bays, gradient amplifier, diverse amplifiers available
  • Avance3 mini 400 MHz: 2 channel console, gradient amplifier, 60/150 W amplifier board
  • Avance2 mini 400 MHz: 2 channel console, gradient amplifier, 60/150 W amplifier board
  • Avance2 mini 300 MHz: 2 channel console, gradient amplifier, 60/150 W amplifier board

Liquids NMR Probes

  • 500 MHz BBO X{1H} double resonance, no PFG
  • 400 MHz 5 mm BBO ATM X{1H} double resonance, PFG, Auto-tuning (ATMA)
  • 400 MHz 5 mm BBI ATM 1H{X} double resonance inverse, PFG, Auto-tuning (ATMA)
  • 400 MHz 5 mm SEI ATM 1H{13C} double resonance, PFG, Auto-tuning
  • 400 MHz 5 mm QNP 19F/31P/13C{1H} double resonance, PFG
  • 400 MHz 10 mm BBO (for WB magnets) X{1H} double resonance, no PFG
  • 300 MHz 5 mm BBO 13C{1H} double resonance, PFG, Auto-tuning (ATMA)
  • 300 MHz 10 mm BBO X{1H} double resonance, no PFG
  • 300 MHz 5 mm BBI 1H{X} double resonance inverse, no PFG
  • 300 MHz 5 mm CH 13C{1H} double resonance, no PFG
  • 200 MHz 5 mm QNP 19F/31P/13C{1H} double resonance, PFG

Solids NMR Probes

  • 500 MHz HP WB 73 15N-31P{19F-1H} double resonance MAS 4 mm BL CP BB DVT
  • 400 MHz HP WB 73 13C-31P{19F-1H} double resonance MAS 2.5 mm BL CP BB DVT
  • 400 MHz HRMAS 15N-31P{1H} double resonance HR-MAS with PFG

Sample Changers

  • BACS60 (60 samples) autosampler, new version
  • BACS120 (120 samples) autosampler, new version


Amplifiers

  • BLARH1-10
  • 200-600 MHz 10 W (1H)
  • BLAXH50
  • 200-400 MHz 100 W (X) + 50 W (1H)
  • BLARH100
  • 750-850 MHz 100 W
  • BLA2BB board
  • 20-400 MHz 150 W (X) + 60 W (1H)
  • BLARH100
  • 200-600 MHz 100 W (1H)
  • BLARH100RS
  • 500-600 MHz 100 W (1H)
  • BLAX300RS
  • 6-242 MHz 300 W (X)
  • BLAX300RS
  • 6-325 MHz 300 W (X)
  • BLAX300
  • 6-365 MHz 300 W (X)
  • BLAX300 board
  • 6-243 MHz 300 W (X)
  • BLAXH300/100
  • 200-600 MHz 300 W (X) + 100 W (1H)
  • BLAX500
  • 6-365 MHz 500 W (X)
  • BLAH1000
  • 200-600 MHz 1000 W (1H)
  • BLAX1000
  • 30-325 MHz 1000 W (X)
  • BLA1000-I
  • 15-400 MHz 1000 W (X)
  • BLPPA20010
  • 185-200 MHz 2000 W

Air Chillers

  • FTS-80 preconditioning unit: -80...+100 deg. C air chiller/heater (min. sample temp typically -50 deg. C, min. air dewpoint required: -100)
  • FTS-40 preconditioning unit: -40...+100 deg. C air chiller/heater (min. sample temp typically -20 deg. C, min. air dewpoint required: -60)
  • 50 l nitrogen dewar with heat exchanger: for long-time low-temperature work (needs nitrogen gas supply)
  • Bruker BCU-05: -20 deg. C air chiller (min. sample temp typically -5...-15 deg. C, min. air dewpoint required: -40)
  • Bruker nitrogen gas generator: for long-time low-temperature work (nitrogen dewar included, BVT to control)

Upgrades

  • Older DRX to AV1 upgrade: Complete console upgrade including all required parts and installation (keep your magnet, much of the console and probes). Supports max. Topspin 2.1 (Windows XP/Centos 6/7), computer on request.
  • Older (DRX or AV1) to newer (AV2 or AV3) upgrade: Complete console upgrade including all required parts and installation (keep your magnet, most of console and probes). Supports max. Topspin 3.7 (Windows 10/Centos 6/7), computer on request.
  • AV1 Receiver upgrade: Replace standard SADC (100 kHz max. spectral width) with HADC digitizer (max. 1 MHz spectral width)

Spare parts/Accessories

  • Avance AQS/AQS2 boards: SGU600, SGU400, RX22, SADC, HADC/2, REF22, REF400-22, Router3/5, CCU11, CCU10, CCU8, GCU, FCU4/4, FCU3, TCU3/4, RCU1/2, ACB-X
  • Avance AQR boards: ASU1, ASU2, LOT, ACB
  • Avance BSMS boards: CPU/3, CPU/2, LCB, SLCB, SLCB/2, L-TX200/300/400/600, L-RX200/300/400/600, 2H-TX200-400, 2H-TX500-900
  • Avance shim boards: SCB7M-16bit, SCB13R-16bit, SCB13L-16S, SCB13M-16S, SCB13R-2OU br>
  • Avance preamps: Diverse HPPR, HPPR/2
  • Avance gradient amplifiers: GAB board, GREAT 1/10
  • Temperature controllers: BVT3000, BVT3200 (board), BVT3300
  • Shim tubes: BOSS1, BOSS2, for diverse narrow- and wide bore magnet sizes
  • BST Upper Part: For diverse narrow- and wide bore magnet sizes
  • MAS controllers: MAS1, MAS2
  • PTS frequency synthesizers: DL620V002SX-88, DL310V002SX-88
  • Diverse Power supplies, cables etc.
  • RF filters for liquids and solids NMR (or other uses). A large variety of frequencies is available, bandpass, high- or lowpass and notch filters, low-power versions for liquids NMR as well as high-power (kW) for solids.
  • Sample spinners: 5 mm (room-temperature only)

Ask for a quotation


Your used systems/parts

Do you have any used NMR system(s) or spares you no longer need and want to get rid of?
Please contact me!



Updated 11 Sep 2025